ISRCTN ISRCTN15470049
DOI https://doi.org/10.1186/ISRCTN15470049
Secondary identifying numbers 1.0
Submission date
10/05/2018
Registration date
23/05/2018
Last edited
10/05/2021
Recruitment status
No longer recruiting
Overall study status
Completed
Condition category
Respiratory
Prospectively registered
Protocol
Statistical analysis plan
Results
Individual participant data

Plain English summary of protocol

Background and study aims
The diaphragm is the main muscle helping breathing. This study aims to check the use of MRI in patients with diaphragmatic weakness and patients with COPD (emphysema and chronic bronchitis) who have hyperinflation. In some patients with COPD, air gets trapped in the lungs and causes them to expand too much; this is called hyperinflation. These patients report severe breathlessness, which may be in part because of their diaphragm. It is known that posture affects lung function and breathing and this study will check the effect of posture on the diaphragm. Currently, lung function tests and CT or ultrasound scan are the main tests that are used to check how the diaphragm works. Recently, at University of Nottingham, an imaging approach has been developed using an upright MRI to test patients in a lying position and seated/standing in the same scanner. This may help to test the diaphragm position and shape more accurately and check the effects of posture on the diaphragm. This may help researchers to better understand the relationship between postural changes in diaphragm position and shape and symptoms.

Who can participate?
Healthy volunteers, patients with diaphragmatic weakness and patients with COPD whose lungs are over-expanded

What does the study involve?
Participants are asked to attend the imaging centre only once, where they are scanned at the same visit, which is expected to take 2 hours to complete. They are scanned on two scanners: lying and seated/standing in the new upright scanner and lying in a conventional scanner. The change in diaphragm position and shape caused by a change in posture is assessed, along with impairment in diaphragm movement in COPD patients with hyperinflation.

What are the possible benefits and risks of participating?
Participants will not benefit directly, but the results may help with the use of this test for people who have lung problems. This may give doctors new options for monitoring lung function in these groups of people. The test is not invasive, and there should be no long-term side effects. The scanner does not involve x-rays so does not carry the same risks as CT scans or chest x-rays. MRI uses radio waves similar to those used in radio and TV transmissions. These have a much lower energy than x-rays and as such are considered safe. Strict national safety guidelines are followed, which are designed to prevent the possible hazards of MRI, which are burns and electric shocks. While there is no evidence to suggest that MRI is harmful during pregnancy, it is not advised to scan pregnant women at fields above 2.5T (2.5 Tesla). The magnets we use are 0.5T and either 1.5T or 3T scanners. All premenopausal female participants are asked to give a urine sample to test for pregnancy at the study visit before scanning. Another risk of having an MRI scan may be the feeling of claustrophobia so patients who have claustrophobia should not take part in this study.

Where is the study run from?
The study takes place at the clinical research MRI centre at Nottingham Medical School, which is next to Queen’s Medical Centre

When is the study starting and how long is it expected to run for?
March 2018 to April 2020

Who is funding the study?
University of Nottingham (UK)

Who is the main contact?
Dr Shahideh Safavi

Contact information

Dr Shahideh Safavi
Scientific

Respiratory Medicine Office
South Block, D Floor
Queen's Medical Centre
Nottingham
NG7 2UH
United Kingdom

Study information

Study designProof-of-concept clinical trial
Primary study designObservational
Secondary study designCohort study
Study setting(s)Other
Study typeDiagnostic
Participant information sheet Not available in web format, please use the contact details to request a patient information sheet
Scientific titleUpright magnetic resonance imaging in COPD and diaphragm disease
Study objectivesTo assess the role of MRI in diagnosing and assessing severity of abnormalities in diaphragm morphology and position in patients with diaphragmatic weakness and patients with COPD with hyperinflation.
Ethics approval(s)1. Wales Research Ethics Committee 6, 15/05/2018, ref: 18/WA/0148
2. HRA and Health and Care Research Wales (HCRW), 16/05/2018, IRAS project ID 243925
Health condition(s) or problem(s) studiedDiaphragmatic weakness or COPD (chronic obstructive pulmonary disease) with hyperinflation
InterventionAll participants (healthy individuals and patients) will undergo the following tests/procedures:
1. Relevant Past Medical History Including medication history & smoking status.
2. St George’s Respiratory Questionnaire
3. MRC Dyspnoea score
4. MRI safety questionnaire
5. Height and weight measurement
6. Vital signs measurement (respiratory rate, oxygen saturations, heart rate, blood pressure)
7. Spirometry
8. Urine pregnancy test for premenopausal women
9. MRI scan using the open upright MRI scanner and a conventional 1.5T or 3T MRI scanner

MRI scan procedure
MRI scan of thorax (including the lungs and diaphragm) will be performed on the Paramed 0.5T MRI scanner and the 1.5T or 3T scanners, located in the SPMIC-QMC. The participant will be imaged in lying and seating/standing positions. For each posture, they will be scanned after full inspiration and also after full expiration.

Following completion of scanning, to assess the impact on posture on perception of breathlessness, participants will be asked to fill a visual analogue scale for breathlessness for scanning in horizontal and vertical positions.

No contrast agents will be administered to the participant. They will be contacted by phone 24 hours later to monitor wellbeing.
Intervention typeOther
Primary outcome measure1. Change in diaphragm position and morphology caused by a change in posture (vertical to horizontal position or vice versa), measured by analysis of MR images once during the one scan visit. Analysis is performed using Matlab software
2. Degree of impairment in diaphragm movement in COPD patients with hyperinflation, measured once during the one scan visit. Analysis is performed using Matlab software. Patient scans are compared to healthy volunteer scans
3. Correlation between lung function abnormality with abnormalities in diaphragm movement as noted on MRI. Spirometry and scan are performed on the same day during the scan visit
Secondary outcome measuresTolerability data on the ability of participants of each group to adhere to the protocol thus informing the study design of future trials. Participants are asked to fill a visual analogue scale for breathless comparing the severity of breathless in lying and seated positions, right after completing the scans
Overall study start date01/03/2018
Completion date30/04/2020

Eligibility

Participant type(s)Mixed
Age groupAdult
Lower age limit18 Years
SexBoth
Target number of participants20 per cohort (80 in total)
Total final enrolment31
Key inclusion criteriaHealthy volunteers and patients with diaphragm weakness (due to neuromuscular disease, e.g. motor neuron disease, and non-neuromuscular disease e.g. trauma) and patient with COPD with hyperinflation

General inclusion criteria:
1. Adult - male or female, aged 18 to 90 years old
2. Capacity to give informed consent
3. Able to hold their breath for 10 seconds
4. Able to understand the requirements of the study and to cooperate with the study procedures

Cohort-specific inclusion criteria:

Healthy participants:
1. No reported or diagnosed chronic respiratory disease

COPD with hyperinflation:
1. Evidence of airflow obstruction on spirometry – FEV1/FVC < 0.7 and FEV1 <80%
2. Diagnosis of hyperinflation based on imaging or lung function measures

Diaphragm weakness due to non-neuromuscular disease:
1. Established diagnosis of diaphragm weakness due to non-neuromuscular disease, e.g. viral illness, trauma

Diaphragm weakness due to neuromuscular disease:
1. Established diagnosis of diaphragm weakness due to neuromuscular disease
Key exclusion criteria1. Unsuitable for MRI scanning (e.g. have metal implants or pacemaker or contraindicated following questionnaire)
2. Deemed unlikely to comply with instructions during imaging
3. Deemed not fit enough to tolerate procedure
4. Deemed unsuitable by clinical investigator for other reasons
5. History of lung volume reduction procedure
Date of first enrolment01/06/2018
Date of final enrolment30/04/2020

Locations

Countries of recruitment

  • England
  • United Kingdom

Study participating centres

University of Nottingham
NG7 2RD
United Kingdom
Nottingham University Hospitals NHS Trust
NG7 2UH
United Kingdom

Sponsor information

University of Nottingham
University/education

Research Governance Office
East Atrium Jubilee Conference centre
Jubilee Campus
Wollaton Road
Nottingham
NG8 1BB
England
United Kingdom

ROR logo "ROR" https://ror.org/01ee9ar58

Funders

Funder type

University/education

University of Nottingham
Private sector organisation / Universities (academic only)
Location
United Kingdom

Results and Publications

Intention to publish date30/04/2021
Individual participant data (IPD) Intention to shareYes
IPD sharing plan summaryOther
Publication and dissemination planStudy protocol will be made available to other researchers if they approach the investigators. At present, the trialists do not intend to make it available online. The trialists plan to publish the results in a high-impact peer reviewed journal within a year after overall trial end date. Interim results may also be published. The results will also be presented at regional, national, and international conferences. Part of the results may be used in students’ PhD thesis. Participants will not be identified in any publications arising from the research. The data obtained may be published without any identifying information.
IPD sharing planThe data sharing plans for the current study are unknown and will be made available at a later date. This is because the patient cohorts are very niche, and even partially anonymised data is at risk of exposing patients’ identities, and patients have asked for their data to remain anonymised. The anonymised dataset will be stored on the University of Nottingham’s servers securely for seven years. During this time, all precautions will be taken by all those involved to maintain participants’ confidentiality, only members of the research team will have access to participants’ personal data. This has been clearly stated in the Participant Information Sheet and participants are asked to provide consent to this prior to recruitment.

Study outputs

Output type Details Date created Date added Peer reviewed? Patient-facing?
Results article 01/09/2020 10/05/2021 Yes No
HRA research summary 28/06/2023 No No

Editorial Notes

10/05/2021: The following changes have been made:
1. Publication reference added.
2. The total final enrolment number has been added from the reference.