Effect of a dynamic positioning–assisted dialysis nursing model on dry weight attainment

ISRCTN ISRCTN10060219
DOI https://doi.org/10.1186/ISRCTN10060219
Sponsor Gezhouba Central Hospital of Sinopharm
Funder Investigator initiated and funded
Submission date
03/07/2026
Registration date
11/07/2026
Last edited
08/07/2026
Recruitment status
Recruiting
Overall study status
Ongoing
Condition category
Urological and Genital Diseases
Prospectively registered
Protocol
Statistical analysis plan
Results
Individual participant data
Record updated in last year

Plain English summary of protocol

Not provided at time of registration

Contact information

Mr Hua Ao
Principal investigator, Scientific, Public

Gezhouba Central Hospital of Sinopharm
Yichang City
443002
China

Email aoowaoo@163.com

Study information

Primary study designInterventional
AllocationRandomized controlled trial
MaskingBlinded (masking used)
ControlUncontrolled
AssignmentParallel
PurposeDevice feasibility
Scientific titleEffect of a dynamic positioning–assisted dialysis nursing model on dry weight attainment
Study objectives Based on the concept of the Hydrostatic Indifference Plane (HIP), investigate the hemodynamic effects of the combined Passive Leg Raising (PLR) and Tilt position on maintenance hemodialysis (MHD) patients, with a focus on preventing intradialytic hypotension (IDH) and hypertension during dialysis blood reinfusion, thereby improving the achievement rate of Dry Weight (DW).
Ethics approval(s)

Submitted 25/02/2022, Ethics Committee of China Three Gorges University (Gezhouba Central Hospital of Sinopharm, Yichang City, 443002, China; +86 139 7200 0727; -), ref: 2022BA002

Health condition(s) or problem(s) studiedMaintenance hemodialysis
Intervention72 MHD patients were randomly divided into an observation group and a control group (36 each). Computer-generated block randomisation (block size 6) was used with allocation concealed with sequentially numbered opaque sealed envelopes.

Intervention: Dynamic positioning dialysis nursing model guided by relative blood volume monitoring, including passive leg raising during ultrafiltration and sequential tilt/sitting posture adjustment during blood reinfusion, delivered 3 times weekly over 3 months. Comparator: Standard maintenance haemodialysis with fixed supine position and no positional intervention.

Using the Fresenius 4008S dialyzer's relative blood volume (RBV) monitoring, the control group stopped ultrafiltration when the RBV curve dropped sharply, while the observation group maintained PLR. If the RBV curve rebounded, ultrafiltration was resumed with an extra 150–500 ml; if it plateaued, the current weight was set as provisional DW. The study compares the overhydration (OH), total body water (TBW), extracellular water (ECW), intracellular water (ICW), as well as the systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean arterial pressure (MAP) at the start of dialysis, the end of ultrafiltration, and the end of dialysis blood reinfusion between the two groups. Over 3 months, indicators like IDH incidence, ultrafiltration adjustments, overhydration (OH), TBW, ECW, ICW and DW compliance rate were compared.
Intervention typeDevice
PhasePhase III
Drug / device / biological / vaccine name(s)Dynamic positioning–assisted dialysis nursing model
Primary outcome measure(s)
  1. Achievement rate of dry weight measured using thoracic bioelectrical impedance analysis (NICaS BIA) at baseline and 3-month follow-up
Key secondary outcome measure(s)
  1. Incidence of intradialytic hypotension (IDH) measured using real-time bedside blood pressure monitoring at each 4-hour dialysis session over 3 months
  2. Overhydration (OH), total body water (TBW), extracellular water (ECW), intracellular water (ICW), ECW/TBW and ECW/ICW ratios measured using NICaS BIA at baseline and 3-month follow-up
  3. Systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean arterial pressure (MAP) measured using electronic sphygmomanometer at dialysis initiation, end of ultrafiltration and completion of blood reinfusion per session
  4. Mean ultrafiltration volume and relative blood volume (RBV) fluctuation measured using Fresenius 4008S dialysis machine BVM monitoring system at each dialysis session for 3 months
Completion date03/07/2028

Eligibility

Participant type(s)
Age groupMixed
Lower age limit18 Years
Upper age limit75 Years
SexAll
Target sample size at registration72
Total final enrolment72
Key inclusion criteria1. MHD duration of more than 6 months
2. Independent in daily activities
3. Receiving regular HD sessions three times per week
Key exclusion criteria1. Patients with fractures, spinal deformities, or impaired self-care ability
2. History of severe hepatic, pulmonary, or neurological diseases
3. Body mass index (BMI) <18.5 kg/m² (underweight)
Date of first enrolment03/07/2026
Date of final enrolment03/07/2028

Locations

Countries of recruitment

  • China

Study participating centres

Results and Publications

Individual participant data (IPD) Intention to shareNo

Editorial Notes

08/07/2026: Study’s existence confirmed by the Ethics Committee of China Three Gorges University.