Breath-hold during robotic bronchoscopy for lung nodule biopsy
| ISRCTN | ISRCTN11802169 |
|---|---|
| DOI | https://doi.org/10.1186/ISRCTN11802169 |
| Sponsor | Winro Ventures LLC |
| Funder | Winro Ventures LLC |
- Submission date
- 28/08/2026
- Registration date
- 01/09/2026
- Last edited
- 01/09/2026
- Recruitment status
- No longer recruiting
- Overall study status
- Ongoing
- Condition category
- Respiratory
Plain English summary of protocol
Background and study aims
Lung nodules and other unusual areas in the lung sometimes need a biopsy to find out whether they are cancer or another condition. Robotic bronchoscopy is a minimally invasive procedure that uses a robotic system and imaging to guide biopsy tools through the airways to reach these areas.
The aim of this study, called STABLE, is to find out whether briefly holding a patient's breathing during tissue sampling can improve the success of robotic bronchoscopy. Researchers want to know if this approach helps keep the biopsy tool in the correct position and increases the chance of obtaining an accurate diagnosis. The study will also look at how well lung lesions can be located, the amount of radiation used, the number of biopsy samples taken, and any complications that occur.
Who can participate?
Adults aged 18 years or older who have a peripheral lung lesion that requires a diagnostic biopsy may be able to take part. Participants must already be scheduled to undergo robotic bronchoscopy using advanced imaging techniques and be able to have the procedure under general anaesthesia. They must also be willing and able to provide written informed consent.
What does the study involve?
This is a randomised study involving 150 participants. Before the procedure, participants are allocated by chance to one of two groups.
One group has sustained breath-hold ventilation during tissue sampling. The other group has conventional ventilation during tissue sampling. Apart from this difference, both groups undergo the same standard robotic bronchoscopy and imaging procedures.
During the procedure, doctors collect tissue samples from the lung lesion for testing. Researchers then compare how often the procedure provides a clear diagnosis in each group. Participants may also be followed through their medical records so that researchers can confirm the final diagnosis if needed.
What are the possible benefits and risks of participating?
Participants may not receive any direct benefit from taking part. However, the information collected could help improve robotic bronchoscopy procedures for future patients with lung lesions.
The risks are similar to those normally associated with robotic bronchoscopy and lung biopsy procedures. These include pneumothorax (a collapsed lung) that may require a chest tube and bleeding that may require medical treatment. Participants will also be exposed to radiation from the imaging used during the procedure. The study will monitor these events carefully.
Where is the study run from?
Winro Ventures LLC (USA)
When is the study starting and how long is it expected to run for?
January 2025 to October 2027
Who is funding the study?
Winro Ventures LLC (USA)
Who is the main contact?
Dr Roshen Mathew, mathew.roshen@gmail.com
Contact information
Public, Scientific, Principal investigator
West Virginia University
Camden Clark Medical Center
Parkersburg
26101
United States of America
| 0000-0002-4338-1259 | |
| Phone | +1 (0)5164748974 |
| rm11092@wvumedicine.org |
Study information
| Primary study design | Interventional |
|---|---|
| Allocation | Randomized controlled trial |
| Masking | Blinded (masking used) |
| Control | Active |
| Assignment | Sequential |
| Purpose | Diagnostic |
| Scientific title | Study of Tool-lesion Alignment and Breath-hold ventilation in robotic bronchoscopy for peripheral lung LEsions (STABLE) |
| Study acronym | STABLE |
| Study objectives | Primary objective: To determine whether sustained breath-hold during tissue acquisition improves strict diagnostic yield during imaging-integrated robotic bronchoscopy compared with conventional ventilation Hypothesis: Sustained breath-hold during tissue acquisition will improve strict diagnostic yield by reducing respiratory movement of the target lesion and improving stability of the lesion-biopsy tool relationship Secondary endpoints: 1. Successful lesion localization using integrated imaging 2. Imaging-confirmed tool-lesion relationship: tool-in-lesion (TIL), tool-touching-lesion (TTL), or no tool in lesion (NTL) 3. Diagnostic yield according to imaging-confirmed tool-lesion position 4. Radiation exposure, including fluoroscopy time, cumulative air kerma, dose-area product, and number of C-arm spins 5. Procedural sampling measures, including number of transbronchial needle aspiration passes and transbronchial forceps biopsy specimens 6. Number of sustained breath-holds performed in the breath-hold group 7. Clinically significant complications, including pneumothorax requiring chest-tube placement and clinically significant bleeding requiring intervention 8. Longitudinal diagnostic accuracy following clinical, imaging, surgical, or other definitive follow-up when available |
| Ethics approval(s) | Ethics approval not required |
| Health condition(s) or problem(s) studied | Peripheral pulmonary lesions requiring diagnostic biopsy |
| Intervention | This is a prospective randomized study. After enrollment and before the procedure, patients are individually randomized to sustained breath-hold or conventional ventilation using computer-based simple randomization with equal probability of assignment. Assignment is generated at the time of randomization, with no pre-generated allocation sequence available to the procedural team. Intervention arm: Sustained breath-hold ventilation: Participants underwent robotic bronchoscopy under general anesthesia with mechanical ventilation. Augmented fluoroscopy and C-arm–based tomosynthesis were used for lesion localization and confirmation of tool position, with brief breath-hold during imaging acquisition as required by the imaging workflow. During tissue acquisition, ventilation was held using a standardized sustained breath-hold strategy while transbronchial needle aspiration and/or transbronchial biopsy specimens were obtained. Breath-hold was repeated as clinically appropriate and could be discontinued at any time if required for patient safety. Control arm: Conventional ventilation: Participants underwent the same robotic bronchoscopy, anesthesia, imaging, lesion localization, and tissue-sampling procedures. Brief breath-hold was similarly used during augmented fluoroscopy and C-arm–based tomosynthesis imaging acquisition. However, during tissue acquisition, conventional mechanical ventilation was resumed/continued rather than maintaining sustained breath-hold. Duration and follow-up: The randomized intervention was limited to the robotic bronchoscopy procedure. No additional treatment was administered as part of the study. Participants received routine post-procedure care and were subsequently followed through the medical record and available clinical and imaging follow-up to establish the final diagnosis and assess diagnostic accuracy. |
| Intervention type | Procedure/Surgery |
| Primary outcome measure(s) |
|
| Key secondary outcome measure(s) |
1. Lesion localization success measured using intraprocedural robotic navigation, augmented fluoroscopy, and C-arm–based tomosynthesis imaging during the index robotic bronchoscopy |
| Completion date | 30/10/2027 |
Eligibility
| Participant type(s) | |
|---|---|
| Age group | Mixed |
| Lower age limit | 18 Years |
| Upper age limit | 100 Years |
| Sex | All |
| Target sample size at registration | 100 |
| Total final enrolment | 150 |
| Key inclusion criteria | 1. Adults aged ≥18 years 2. Presence of a peripheral pulmonary lesion requiring diagnostic biopsy 3. Scheduled to undergo robotic bronchoscopy with augmented fluoroscopy and C-arm–based tomosynthesis for tissue acquisition 4. Able to undergo the procedure under general anesthesia with mechanical ventilation 5. Able and willing to provide written informed consent as required for robotic bronchoscopy procedure |
| Key exclusion criteria | 1. Age <18 years 2. Inability or unwillingness to provide informed consent 3. Inability to safely undergo general anesthesia or mechanical ventilation 4. Clinical or anesthetic circumstances in which sustained breath-hold ventilation was considered unsafe or not feasible 5. Inability to undergo the planned robotic bronchoscopy procedure |
| Date of first enrolment | 01/01/2025 |
| Date of final enrolment | 30/06/2026 |
Locations
Countries of recruitment
- United States of America
Study participating centres
Results and Publications
| Individual participant data (IPD) Intention to share | No |
|---|
Study outputs
| Output type | Details | Date created | Date added | Peer reviewed? | Patient-facing? |
|---|---|---|---|---|---|
| Protocol file | 28/08/2026 | No | No |
Additional files
- 50182 STABLE_WVU_Camden_Clark_IRB_Protocol ISRTCN.pdf
- Protocol file
Editorial Notes
01/09/2026: Study's existence confirmed by West Virginia University.