ISRCTN ISRCTN60377452
DOI https://doi.org/10.1186/ISRCTN60377452
Protocol serial number 2014-19
Sponsor Shanghai Jiaotong University affiliated Shanghai Sixth People’s hospital
Funder Investigator initiated and funded
Submission date
01/12/2016
Registration date
05/12/2016
Last edited
11/07/2018
Recruitment status
No longer recruiting
Overall study status
Completed
Condition category
Surgery
Prospectively registered
Protocol
Statistical analysis plan
Results
Individual participant data

Plain English summary of protocol

Background and study aims
Cannulation is a commonly used medical procedure where a small tube is inserted into a vein or artery for access. Radial artery (the main artery in the forwarm) cannulation is used routinely in clinical settings for many purposes, such as accurate monitoring of beat-to-beat blood pressure, repeated multiple blood sampling and some surgical procedures. The radial artery is small, and so can be very difficult to cannulate however. Multiple attempts to cannulate can be risky and lead to risk and complications such as temporarily blocking the artery (occlusion), blood clots and bleeding. It is therefore important to find an easy, convenient and quick method for accessing the radial artery. In recent years, ultrasound (US) devices have been used to visualise blood vessels in order to access them with a cannula. Additionally use of a tourniquet (tight band to cut of blood supply) can also help improve cannulation success rates. The aim of this study is to find our whether using a tourniquet can improve the success rate of radial artery cannulation when using ultrasound.

Who can participate?
Adults undergoing major non-emergency surgery who require continuous beat-to-beat blood pressure monitoring throughout their operation.

What does the study involve?
Participants are randomly allocated to one of two groups. Those in the first group have a tourniquet tied as tightly as possible around the arm. Those in the second group have a tourniquet loosely tied on the far-end of the wrist. Following this, participants in both groups are cannulated using an ultrasound probe to visualise the artery. The time taken to successfully place the cannula is recorded for participants in both groups.

What are the possible benefits and risks of participating?
Participants could benefit from improved success rates of cannulation and a shorter cannulation time. There are no notable risks of participating other than the general risks associated with cannulation, such as pain or bruising.

Where is the study run from?
Shanghai Jiaotong University Affiliated Shanghai No.6 People’s Hospital (China)

When is the study starting and how long is it expected to run for?
March 2014 to December 2016

Who is funding the study?
Investigator initiated and funded (China)

Who is the main contact?
Ms Quanhong Zhou

Contact information

Miss Quanhong Zhou
Scientific

600 Yishan Road
Shanghai
200233
China

Study information

Primary study designInterventional
Study designRandomised parallel trial
Secondary study designRandomised parallel trial
Study type Participant information sheet
Scientific titleWhen tourniquet meets ultrasound for radial artery cannulation: a way to improve the quality of monitoring
Study objectivesDistal tightened tourniquet may facilitate ultrasound guided radial artery cannulation.
Ethics approval(s)Institutional Review Board of Shanghai Jiaotong University-affiliated Shanghai No.6 People’s Hospital, 26/03/2014, ref: 2014-19
Health condition(s) or problem(s) studiedRadial artery cannulation
InterventionParticipants are randomly allocated to one of two groups using the sealed envelope technique. In both groups, the tourniquet is placed distally to the ulnar styloid process.

Group 1: The tourniquet is tied as tightly as possible

Group 2: The tourniquet is loosely tied on the far-end of the wrist

Following application of the tourniquet, an assistant sterilizes the forearm skin and put a sheet with hole at the insertion site to cover the tourniquet. Doctor could not see the tourniquet when performing the cannulation. An ultrasound probe is used to search for the optimal site for needle insertion and the needle is inserted at the center of the probe. If blood flushes out, the sheath of the needle is inserted and the needle taken out. The sheath is then connected to monitor (CARESCAPE, GE) via a pressure sensor (Combitrans Arterial Monitoring Kit B/BRAUN). A successful cannulation is announced when an arterial wave is shown on the monitor. The time from needle insertion to the successful wave shown is defined as radial artery cannulation time.
Intervention typeProcedure/Surgery
Primary outcome measure(s)

First-attempt success rate is measured by how many patients had first-attempt success out of the whole population in his/her group (n=120) at the end of the study.

Key secondary outcome measure(s)

1. Number of attempts is counted and verified using ultrasound scanning
2. Failure rate is measured by how many patients had failed out of the whole population in his/her group (n=120) at the end of the study
3. Time used for cannulation is measured using stopwatch by assistant at the process of cannulation
4. Frequency of posterior wall technique used is measured by how many patients had posterior wall technique out of the whole population in his/her group (n=120) at the end of the study

Completion date01/12/2016

Eligibility

Participant type(s)Patient
Age groupMixed
Lower age limit18 Years
SexAll
Target sample size at registration240
Key inclusion criteria1. Aged 18 years and over
2. Undergoing elective major surgery
3. Assumed to require continuous blood pressure monitor during their operation
Key exclusion criteria1. Patients with abnormal Allen test
2. Peripheral vascular diseases
3. Scars at the forearm i.e. insertion site
Date of first enrolment07/04/2014
Date of final enrolment01/12/2015

Locations

Countries of recruitment

  • China
  • Christmas Island

Study participating centre

Shanghai Jiaotong University Affiliated Shanghai No.6 People’s Hospital
600 Yishan Road
Shanghai
200233
China

Results and Publications

Individual participant data (IPD) Intention to shareYes
IPD sharing plan summaryAvailable on request
IPD sharing planThe datasets generated during and/or analysed during the current study are/will be available upon request from Quanhong Zhou, zhouanny@hotmail.com

Study outputs

Output type Details Date created Date added Peer reviewed? Patient-facing?
Results article results 01/04/2018 Yes No
Participant information sheet Participant information sheet 11/11/2025 11/11/2025 No Yes

Editorial Notes

11/07/2018: Publication reference added.